Operation CHARM: Car repair manuals for everyone.

2.0L






Generator

Observe notes on contact corrosion. Refer to=> [ Contact Corrosion ] Contact Corrosion.

Removing






- Turn off the ignition and disconnect the ground cable from the battery. Refer to => [ Battery, Disconnecting and Connecting ] Service and Repair.

- Release the tension on the ribbed belt and remove it from the generator pulley.

- Remove the bolts - arrows - and move the generator forward.

- Disconnect the electrical connector - 1 -.






- Remove terminal 30/B+ - item 2 -.

- Remove the generator.

Installing

• Tightening specifications, refer to => [ Generator Overview ] Generator Overview.

Install in reverse order of removal. Note the following:

- Install the ribbed belt.

- Connect the battery. Required actions, refer to=> [ Connecting ] Service and Repair.

- Start the engine and check the ribbed belt routing.