2.0L
Generator
Observe notes on contact corrosion. Refer to=> [ Contact Corrosion ] Contact Corrosion.
Removing
- Turn off the ignition and disconnect the ground cable from the battery. Refer to => [ Battery, Disconnecting and Connecting ] Service and Repair.
- Release the tension on the ribbed belt and remove it from the generator pulley.
- Remove the bolts - arrows - and move the generator forward.
- Disconnect the electrical connector - 1 -.
- Remove terminal 30/B+ - item 2 -.
- Remove the generator.
Installing
• Tightening specifications, refer to => [ Generator Overview ] Generator Overview.
Install in reverse order of removal. Note the following:
- Install the ribbed belt.
- Connect the battery. Required actions, refer to=> [ Connecting ] Service and Repair.
- Start the engine and check the ribbed belt routing.