Operation CHARM: Car repair manuals for everyone.

Ignition Coil: Testing and Inspection




Ignition Coils With Power Output Stages, Checking







Special tools and equipment
- VAG1526A
- VAG1527B
- VAG1594A
- VAG1598/31

Test sequence


NOTE: The ignition coil and power output stage are combined in one complete component.







- Remove engine cover (arrows).

Recognize a non-functional or misfiring cylinder as follows:
- Check misfire recognition Testing and Inspection

If misfires were recognized:
- Continue with test at indicated cylinder, see "If faulty cylinder is recognized".

If no misfires were recognized:
- Disconnect connectors from fuel injectors in sequence with engine running and observe engine operation.
or
- Compare spark plugs from all cylinders to each other. Check electrodes for carbon fouling..

If faulty cylinder is recognized:
- Switch spark plug from faulty cylinder with one from another cylinder.

If malfunction follows the spark plug:
- Replace spark plug.

If malfunction remains at original cylinder:
- Switch ignition coil from faulty cylinder with one from another cylinder.

If malfunction follows the ignition coil:
- Replace ignition coil.

Check Ground (GND) connection







- Disconnect 4-pin harness connector -1 - at ignition coil -2-.







- Connect VAG1527B voltage tester as follows:

Harness connector Measure to
Terminal

2 B+
4 B+

- LED must light up.

If LED does not light up:
- Check wire connections.

If LED lights up:
- Check voltage supply

Checking voltage supply

Test requirement:
- Fuses for engine electronics OK







- Connect multimeter for voltage measurement as follows:

Harness connector Measure to
Terminal

1 Engine Ground (GND)

- Switch ignition on.
- Specification: approx. battery voltage

If specified value is obtained:
- Check activation of power output stages.

If specified value is not obtained:







- Pull off rubber seal of plenum chamber cover in direction of arrow.
- Remove cover -1- toward front.







- Remove Heater Core E-box cover (arrows).







- Disconnect voltage supply relay -3-.
- Perform following tests marked with dots:







- Check wire connection from 3-socket relay carrier, position 2, terminal 6 to harness connector at ignition coil terminal 1.
- Check motronic Engine Control Module (ECM) power supply relay -J271-.

Checking activation of power output stages
- Remove all harness connectors to injectors.


NOTE: Fuel must not be injected during the test to avoid damaging catalytic converter. Connectors must therefore be disconnected from fuel injectors.







- Disconnect 4-pin harness connector -1- at ignition coil -2-.







- Connect VAG1527B voltage tester to connector terminals 2 and 3.
- Operate starter briefly.
- LED must blink (brief blink signal).

If specified values are not obtained:
- Connect VAG1598/31 test box at wiring harness to Engine Control Module (ECM), do not connect ECM.






- Check following wire connections for open circuit and short circuit to Ground (GND) and B+:

Harness connector VAG1598/31 test box
Terminal Socket

3 (Cyl. 1) 102
3 (Cyl. 2) 95
3 (Cyl. 3) 103
3 (Cyl. 4) 94

- Repair open circuit or short circuit if necessary.

If no malfunctions are found in wires:
- Replace combined component, ignition coil with power output stage.