EGR Valve: Testing and Inspection
Requirements
- Vacuum lines and intake manifold connections free of leaks
- Vacuum lines not plugged or bent
- Engine oil 50 °C (122 °F) minimum
Checking
- Start engine and let idle.
- Disconnect vacuum hose at EGR valve.
- Connect US 8026 hand vacuum pump to EGR valve using spare piece of hose.
- Operate hand pump to create vacuum.
- Idle quality must degenerate
If NO (idle improves or stays the same):
- Check lines and connections for plugging; replace EGR valve if necessary.