Removal and Replacement
Expansion valve
Replacing the expansion valve
Warning! Follow the appropriate safety precautions when working on the climate control system, see Refrigerant, safety regulations Refrigerant, Safety Regulations.
Note! Read the instructions about slow and large leaks, see Oil in the air conditioning (A/C) system Oil In The Air Conditioning (A/C) System.
Note! Always use new O-rings lubricated with air conditioning (A/C) compressor oil.
Note! Always plug pipes and connectors when working on the climate control system.
Removal
- Remove the evaporator according to Evaporator Removal and Replacement
- Disconnect the connections from the expansion valve. Use two wrenches
- Remove the insulation
- Remove the temperature sensor from the pipe (clip)
- Remove the expansion valve.
Installation
- Assemble the O-rings. Lubricate them with air conditioning (A/C) compressor oil
- Secure the expansion valve by hand. Position it so that it is free of the evaporator. Secure it. Use two wrenches
- Press the temperature sensor onto the pipe
- Reinstall the insulation
- Install the evaporator according to Evaporator Removal and Replacement.
Tightening torque: Heavy duty pipe: 20 Nm, Thin pipe: 15 Nm. Sensor: 12 Nm.
Filling with refrigerant
- Vacuum pump according to Vacuum pumping Vacuum Pumping
- Fill the system with refrigerant according to Filling with refrigerant Filling With Refrigerant
- Fill the system with fluorescent tracing agent according to Filling with fluorescent tracing agent Filling With Fluorescent Tracing Agent
- Leak trace according to Leak tracing, electronic leak tracer Leak Tracing, Electronic Leak Tracer or Leak tracing with fluorescent tracing agent and an UV lamp Leak Tracing, Fluorescent Tracing Agent/UV Lamp.