Test F: High Speed Blower Relay Test
Remove the connector from the relay and measure the voltage to ground with the Blower Speed Control Switch in the positions shown.Test F High Speed Blower Relay Test Part 1 Of 2:
^ If all voltages are correct and relay does not operate, check that terminal B (BLK) is grounded at G200. If ground is good proceed to step 2.
^ If the voltage at a terminal is not correct, check the circuit at that terminal.
2. Put the connector back on the High Speed Blower Relay. Measure the voltage to ground at the PPL wire of the relay.
Test F High Speed Blower Relay Test Part 2 Of 2:
^ If all voltages in steps 1 and 2 are correct, but blower does not operate, complete Test A. Test A: Blower Motor Test
^ If voltages are incorrect, replace relay.