Inspection Procedure K-3
Interior light: Dome light dimming function does not work normally.NOTE: This troubleshooting procedure requires the use of scan tool MB991502 and SWS monitor kit MB991862. For details on how to use the SWS monitor, refer to "How to use SWS monitor."
Interior Light Automatic Shut-down Function Circuit:
CIRCUIT OPERATION
The ETACS-ECU operates the dome light dimming function according to the input signals from the following switches:
- Ignition switch (IG1): OFF
- Key reminder switch: ON
- Door switches: OFF
- Driver's door lock actuator switch: LOCK or UNLOCK
TECHNICAL DESCRIPTION (COMMENT)
Is the dome lights do not dim normally, the input circuits from the switches described in "CIRCUIT OPERATION" or the ETACS-ECU may be defective.
TROUBLESHOOTING HINTS
- The key reminder switch may be defective
- The door switches may be defective
- The driver's door lock actuator switch may be defective
- The ETACS-ECU may be defective
- The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector
DIAGNOSIS
Required Special Tools:
- MB991223: Harness Set
- MB991502: Scan Tool (MUT-II)
- MB991862: SWS monitor kit
STEP 1. Check the dome light.
If a door is opened while the dome light switch is at "door-linked" position, the dome light should illuminate.
Q: Does the dome light illuminate normally?
YES: Go to Step 2.
NO: Refer to Inspection Procedure K-1 "Dome light does not illuminate or go out normally."
STEP 2. Use scan tool MB991502 to select "ECU COMM CHK" on the SWS monitor display.
Check the ETACS-ECU.
CAUTION:
To prevent damage to scan tool MB991502, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991502. Connect the DLC harness before connecting the column-ECU harness. Be sure to connect SWS monitor kit MB991862 after turning on scan tool MB991502.
1. Connect scan tool MB991502 to the data link connector.
2. Turn the ignition switch to the "LOCK" (OFF) position.
3. Operate scan tool MB991502 according to the procedure below to display "ECU COMM CHK."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "ECU COMM CHK."
4. Scan tool MB991502 should show "OK" on the "ECU COMM CHK" menu for the "ETACS ECU" menu.
Q: Is "OK" displayed on the "ETACS ECU" menu?
YES: Go to Step 3.
NO: Refer to Inspection Procedure A-3 "Communication with ETACS-ECU is not possible."
STEP 3. Check the input signal by using "DATA LIST" menu of the SWS monitor.
Check the input signals from the following switches:
- Ignition switch: OFF
- Driver's or front passenger's door: open
Operate scan tool MB991502 according to the procedure below to display "ETACS ECU."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "SWS MONITOR."
4. Select "DATA LIST."
5. Select "ETACS ECU."
Check that normal conditions are displayed on the items described in the table.
Q: Does the scan tool display "IG SW (IG1)" as normal condition?
YES: Go to Step 4.
NO: Refer to Inspection Procedure M-2 "ETACS-ECU does not receive any signal from the ignition switch (IG1)."
STEP 4. Check the input signal by using the pulse check mode of the monitor.
Check the input signals from the following switches:
- key reminder switch
Operate scan tool MB991502 according to the procedure below to display "PULSE CHECK."
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "PULSE CHECK."
Check if scan tool MB991502 sounds or not.
Q: When the key reminder switch and each door switch are operated, does scan tool MB991502 sound in each case?
YES: Replace the ETACS-ECU. Verify that the dome light dimming function works normally.
NO:
- Scan tool MB991502 does not sound when the key reminder switch is operated: Refer to Inspection Procedure N-1 "ETACS-ECU does not receive a signal from the key reminder switch."
- Scan tool MB991502 does not sound whenever each door switch is operated: Refer to Inspection Procedure N-4 "ETACS-ECU does not receive any signal from all the door switches."