Inspection Procedure E-2
Keyless Entry System: None of the doors are locked and unlocked by the keyless entry transmitter.NOTE: This troubleshooting procedure requires the use of scan tool MB991502 and SWS monitor kit MB991862. For details on how to use the SWS monitor, refer to "How to use SWS monitor".
Transmitter ("LOCK/" UNLOCK") Input Circuit:
CIRCUIT OPERATION
A receiver is incorporated in the ETACS-ECU. This receiver receives a lock, unlock or trunk open signal from the transmitter.
TROUBLESHOOTING HINTS
- The transmitter may be defective
- The ETACS-ECU may be defective
DIAGNOSIS
Required Special Tools:
- MB991223: Harness Set
- MB991502: Scan Tool (MUT-II)
- MB991862: SWS Monitor Kit
STEP 1. Check the central door locking system.
Q: Does the central door locking system work normally?
YES: Go to Step 2.
NO: Refer to Inspection Procedure C-1 "Central door locking system does not work at all."
STEP 2. Check the input signal by using the pulse check mode of the monitor.
Check the input signals from the transmitter.
CAUTION:
To prevent damage to scan tool MB991502, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool MB991502.
1. Connect scan tool MB991502 to the data link connector.
2. Operate the MUT-II as follows:
1. Select "SYSTEM SELECT."
2. Select "SWS."
3. Select "PULSE CHECK."
3. Push the transmitter "LOCK" or "UNLOCK" switch.
4. Check that scan tool MB991502 sounds.
Q: When the transmitter "LOCK" or "UNLOCK" switch is pushed, does scan tool MB991502 sound?
YES: Replace the ETACS-ECU. All the doors can be locked or unlocked by means of the transmitter.
NO: Refer to Inspection Procedure N-11 "The ETACS-ECU does not receive signal from lock, unlock, panic or trunk switch".