Pinpoint Test 3: Single Power Window Is Inoperative - Passenger Power Window
PINPOINT TEST 3: SINGLE POWER WINDOW IS INOPERATIVE - PASSENGER POWER WINDOWStep 1:
Step 2-Step 5:
Driver Power Window Switch Component Test:
Passenger Power Window Switch Component Test:
Normal Operation
- Under normal operation, when the driver window control switch is commanding the passenger window down, voltage is sent to the passenger window control switch through circuit (BR/Y) and ground through circuit (G/O). When up is commanded, voltage and ground from the driver window control switch is reversed. Voltage is supplied to the passenger window control switch through circuit (V/W). Ground is provided by the driver window control switch (at rest) through circuits (BR/Y) and (G/O). When the passenger window control switch commands the passenger window down, voltage is sent to the passenger window control motor through circuit (V) and ground through circuit (W/O). When up is commanded, voltage and ground from the passenger window control switch is reversed.
Possible Causes
- An open in circuit (V/W), (BR/Y), (G/O), (V) or (W/O)
- Driver window control switch
- Passenger window control switch
- Passenger window motor
- Smart junction box (SJB)