Operation CHARM: Car repair manuals for everyone.

Pinpoint Test C: A Single Door Lock Is Inoperative




Locks, Latches and Entry Systems






Pinpoint Tests

Pinpoint Test C: A Single Door Lock Is Inoperative

Refer to wiring Diagram Set 117, Remote Keyless Entry and Alarm for schematic and connector information. Diagrams By Number

Normal Operation

The Smart Junction Box (SJB) receives voltage on circuit SBB01 (RD). When the SJB receives a lock signal from a door lock control switch, or a Remote Keyless Entry (RKE) transmitter, the SJB closes the lock relay control circuit. The lock relay closes, supplying voltage to the door lock actuators on circuits CPL11 (GY/BN) and CPL19 (WH/VT) and ground on circuits CPL51 (BU/GN) and CPL18 (GY/VT), locking the doors.

When the SJB receives an unlock signal from a door lock control switch, the SJB closes the driver door unlock relay and the door unlock relay control circuits. The driver door unlock relay closes, supplying voltage to the driver door lock actuator on circuit CPL51 (BU/GN) and ground on circuit CPL11 (GY/BN); and the passenger door unlock relay closes, supplying voltage to the passenger door lock actuator on circuit CPL18 (GY/VT) and ground on circuit CPL19 (WH/VT), unlocking the doors.

When the SJB receives an unlock signal from an RKE transmitter, the SJB closes the driver door unlock relay control circuit, supplying voltage to the driver door lock actuator on circuit CPL51 (BU/GN) and ground on circuit CPL11 (GY/BN), unlocking the driver door; a second unlock signal from the RKE transmitter closes the door unlock relay control circuit, supplying voltage to the passenger door lock actuator on circuit CPL18 (GY/VT) and ground on circuit CPL19 (WH/VT), unlocking the passenger door.

This pinpoint test is intended to diagnose the following:

- Wiring, terminals or connectors
- Door lock actuator
- SJB



PINPOINT TEST C: A SINGLE DOOR LOCK IS INOPERATIVE

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.

-------------------------------------------------
C1 CHECK THE DOOR LATCH FOR BINDING


- Lock and unlock the inoperative door lock using the door lock rod.
- Does the door lock and unlock?

Yes
GO to C3.

No
GO to C2.

-------------------------------------------------
C2 CHECK THE LOCK ROD FOR BINDING


- Operate the door lock rod manually while observing the door lock rod for any binding or if the rod is bent.
- Is the door lock rod bent or binding?

Yes
REPAIR as necessary. TEST the system for normal operation.

No
INSTALL a new door latch. REFER to Front Door Latch Front Door Latch.

-------------------------------------------------
C3 CHECK CIRCUIT CPL11 (GY/BN) OR CIRCUIT CPL19 (WH/VT) FOR VOLTAGE


- Ignition OFF.
- Disconnect: Suspect Door Lock Actuator Connector.
- NOTE: The SJB only supplies voltage to the actuator momentarily. It is important to monitor the meter while pressing the door lock control switch.
- While pressing the door lock control switch in the LOCK position, measure the voltage between the inoperative door lock actuator, harness side and ground as follows:









- Is the voltage momentarily greater than 10 volts?

Yes
GO to C4.

No
GO to C5.

-------------------------------------------------
C4 CHECK CIRCUIT CPL18 (GY/VT) OR CIRCUIT CPL51 (BU/GN) FOR VOLTAGE


- NOTE: The SJB only supplies voltage to the actuator momentarily. It is important to monitor the meter while pressing the door lock control switch.
- While pressing the door lock control switch in the UNLOCK position, measure the voltage between the inoperative door lock actuator, harness side and ground as follows:









- Is the voltage momentarily greater than 10 volts?

Yes
INSTALL a new door lock actuator. REFER to Door Lock Actuator Service and Repair. TEST the system for normal operation.

No
GO to C5.

-------------------------------------------------
C5 CHECK THE DOOR LOCK ACTUATOR CIRCUITS FOR AN OPEN


- Disconnect: SJB C2280b.
- Disconnect: SJB C2280c.
- Measure the resistance between the suspect door lock actuator, harness side and the SJB, harness side as follows:





- Are the resistances less than 5 ohms?

Yes
GO to C6.

No
REPAIR the circuit in question. TEST the system for normal operation.

-------------------------------------------------
C6 CHECK FOR CORRECT SJB OPERATION


- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?

Yes
INSTALL a new SJB. TEST the system for normal operation.

No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

-------------------------------------------------